@@ -46,126 +46,6 @@
|
|
|
*/
|
|
|
// #define XRANDR_DISABLED_BY_DEFAULT
|
|
|
|
|
|
-#ifdef SDL_USE_LIBDBUS
|
|
|
-
|
|
|
-#define SCALE_FACTOR_NODE "org.freedesktop.portal.Desktop"
|
|
|
-#define SCALE_FACTOR_PATH "/org/freedesktop/portal/desktop"
|
|
|
-#define SCALE_FACTOR_INTERFACE "org.freedesktop.portal.Settings"
|
|
|
-#define SCALE_FACTOR_NAMESPACE "org.gnome.desktop.interface"
|
|
|
-#define SCALE_FACTOR_SIGNAL_NAME "SettingChanged"
|
|
|
-#define SCALE_FACTOR_KEY "text-scaling-factor"
|
|
|
-
|
|
|
-static DBusMessage *ReadDBusSetting(SDL_DBusContext *dbus, const char *key)
|
|
|
-{
|
|
|
- static const char *iface = SCALE_FACTOR_NAMESPACE;
|
|
|
-
|
|
|
- DBusMessage *reply = NULL;
|
|
|
- DBusMessage *msg = dbus->message_new_method_call(SCALE_FACTOR_NODE,
|
|
|
- SCALE_FACTOR_PATH,
|
|
|
- SCALE_FACTOR_INTERFACE,
|
|
|
- "Read"); // Method
|
|
|
-
|
|
|
- if (msg) {
|
|
|
- if (dbus->message_append_args(msg, DBUS_TYPE_STRING, &iface, DBUS_TYPE_STRING, &key, DBUS_TYPE_INVALID)) {
|
|
|
- reply = dbus->connection_send_with_reply_and_block(dbus->session_conn, msg, DBUS_TIMEOUT_USE_DEFAULT, NULL);
|
|
|
- }
|
|
|
- dbus->message_unref(msg);
|
|
|
- }
|
|
|
-
|
|
|
- return reply;
|
|
|
-}
|
|
|
-
|
|
|
-static bool ParseDBusReply(SDL_DBusContext *dbus, DBusMessage *reply, int type, void *value)
|
|
|
-{
|
|
|
- DBusMessageIter iter[3];
|
|
|
-
|
|
|
- dbus->message_iter_init(reply, &iter[0]);
|
|
|
- if (dbus->message_iter_get_arg_type(&iter[0]) != DBUS_TYPE_VARIANT) {
|
|
|
- return false;
|
|
|
- }
|
|
|
-
|
|
|
- dbus->message_iter_recurse(&iter[0], &iter[1]);
|
|
|
- if (dbus->message_iter_get_arg_type(&iter[1]) != DBUS_TYPE_VARIANT) {
|
|
|
- return false;
|
|
|
- }
|
|
|
-
|
|
|
- dbus->message_iter_recurse(&iter[1], &iter[2]);
|
|
|
- if (dbus->message_iter_get_arg_type(&iter[2]) != type) {
|
|
|
- return false;
|
|
|
- }
|
|
|
-
|
|
|
- dbus->message_iter_get_basic(&iter[2], value);
|
|
|
-
|
|
|
- return true;
|
|
|
-}
|
|
|
-
|
|
|
-static void UpdateDisplayContentScale(float scale)
|
|
|
-{
|
|
|
- SDL_VideoDevice *viddevice = SDL_GetVideoDevice();
|
|
|
- int i;
|
|
|
-
|
|
|
- if (viddevice) {
|
|
|
- for (i = 0; i < viddevice->num_displays; ++i) {
|
|
|
- SDL_SetDisplayContentScale(viddevice->displays[i], scale);
|
|
|
- }
|
|
|
- }
|
|
|
-}
|
|
|
-
|
|
|
-static DBusHandlerResult DBus_MessageFilter(DBusConnection *conn, DBusMessage *msg, void *data)
|
|
|
-{
|
|
|
- SDL_DBusContext *dbus = SDL_DBus_GetContext();
|
|
|
- double *scale_factor = (double *)data;
|
|
|
- double new_scale = 0.0;
|
|
|
-
|
|
|
- if (dbus->message_is_signal(msg, SCALE_FACTOR_INTERFACE, SCALE_FACTOR_SIGNAL_NAME)) {
|
|
|
- DBusMessageIter signal_iter, variant_iter;
|
|
|
- const char *namespace, *key;
|
|
|
-
|
|
|
- dbus->message_iter_init(msg, &signal_iter);
|
|
|
- // Check if the parameters are what we expect
|
|
|
- if (dbus->message_iter_get_arg_type(&signal_iter) != DBUS_TYPE_STRING) {
|
|
|
- goto not_our_signal;
|
|
|
- }
|
|
|
- dbus->message_iter_get_basic(&signal_iter, &namespace);
|
|
|
- if (SDL_strcmp(SCALE_FACTOR_NAMESPACE, namespace) != 0) {
|
|
|
- goto not_our_signal;
|
|
|
- }
|
|
|
- if (!dbus->message_iter_next(&signal_iter)) {
|
|
|
- goto not_our_signal;
|
|
|
- }
|
|
|
- if (dbus->message_iter_get_arg_type(&signal_iter) != DBUS_TYPE_STRING) {
|
|
|
- goto not_our_signal;
|
|
|
- }
|
|
|
- dbus->message_iter_get_basic(&signal_iter, &key);
|
|
|
- if (SDL_strcmp(SCALE_FACTOR_KEY, key) != 0) {
|
|
|
- goto not_our_signal;
|
|
|
- }
|
|
|
- if (!dbus->message_iter_next(&signal_iter)) {
|
|
|
- goto not_our_signal;
|
|
|
- }
|
|
|
- if (dbus->message_iter_get_arg_type(&signal_iter) != DBUS_TYPE_VARIANT) {
|
|
|
- goto not_our_signal;
|
|
|
- }
|
|
|
- dbus->message_iter_recurse(&signal_iter, &variant_iter);
|
|
|
- if (dbus->message_iter_get_arg_type(&variant_iter) != DBUS_TYPE_DOUBLE) {
|
|
|
- goto not_our_signal;
|
|
|
- }
|
|
|
- dbus->message_iter_get_basic(&variant_iter, &new_scale);
|
|
|
-
|
|
|
- if (new_scale > 0.0) {
|
|
|
- *scale_factor = new_scale;
|
|
|
- UpdateDisplayContentScale((float)new_scale);
|
|
|
- }
|
|
|
-
|
|
|
- return DBUS_HANDLER_RESULT_HANDLED;
|
|
|
- }
|
|
|
-
|
|
|
-not_our_signal:
|
|
|
- return DBUS_HANDLER_RESULT_NOT_YET_HANDLED;
|
|
|
-}
|
|
|
-
|
|
|
-#endif
|
|
|
-
|
|
|
static float GetGlobalContentScale(SDL_VideoDevice *_this)
|
|
|
{
|
|
|
static double scale_factor = 0.0;
|
|
@@ -181,30 +61,6 @@ static float GetGlobalContentScale(SDL_VideoDevice *_this)
|
|
|
}
|
|
|
}
|
|
|
|
|
|
- // Next try the settings portal via D-Bus for the text scaling factor (aka 'Global Scale' on KDE)
|
|
|
-#ifdef SDL_USE_LIBDBUS
|
|
|
- if (scale_factor <= 0.0)
|
|
|
- {
|
|
|
- DBusMessage *reply;
|
|
|
- SDL_DBusContext *dbus = SDL_DBus_GetContext();
|
|
|
-
|
|
|
- if (dbus) {
|
|
|
- if ((reply = ReadDBusSetting(dbus, SCALE_FACTOR_KEY))) {
|
|
|
- if (ParseDBusReply(dbus, reply, DBUS_TYPE_DOUBLE, &scale_factor)) {
|
|
|
- // If the setting exists, register a listener for scale changes.
|
|
|
- dbus->bus_add_match(dbus->session_conn,
|
|
|
- "type='signal', interface='"SCALE_FACTOR_INTERFACE"',"
|
|
|
- "member='"SCALE_FACTOR_SIGNAL_NAME"', arg0='"SCALE_FACTOR_NAMESPACE"',"
|
|
|
- "arg1='"SCALE_FACTOR_KEY"'", NULL);
|
|
|
- dbus->connection_add_filter(dbus->session_conn, &DBus_MessageFilter, &scale_factor, NULL);
|
|
|
- dbus->connection_flush(dbus->session_conn);
|
|
|
- }
|
|
|
- dbus->message_unref(reply);
|
|
|
- }
|
|
|
- }
|
|
|
- }
|
|
|
-#endif
|
|
|
-
|
|
|
// If that failed, try "Xft.dpi" from the XResourcesDatabase...
|
|
|
if (scale_factor <= 0.0)
|
|
|
{
|